EnvironTec Biogas Logo
ENVIRONTEC ASIA HQ
Inquiry
Home (EnvironTec Asia) / Double Membrane Gas Holder & Biogas Gas Holder (DMG Series)
1,000+ INSTALLATIONS · AUSTRIAN ENTEC TECH

Double Membrane Gas Holder & Biogas Gas Holder (DMG Series)

⚡ Engineering Overview & Sizing Principle

EnvironTec Double Membrane Gas Holder (Biogas Gas Holder / DMG Series) provides low-pressure flexible biogas storage from 20 m³ to 6,000+ m³ (up to 20,000 m³ custom). In our official model nomenclature, the primary number denotes total outer membrane volume while the bracketed number indicates effective inner biogas storage volume—for example, a 500 m³/h plant requiring 2 hours of storage (1,000 m³ effective volume) selects Model DMG-1150 (1000m³) with Φ13.75m × 10.31m outer dimensions, 22 mbar operating pressure, and 18 anchor plates.

DMG-25(20) to DMG-7080(6000)

20 standardized civil foundation sizes + Custom-Made tank-top domes.

2-Hour Buffer Recommended

Sized with 15% outer-to-inner volume margin (e.g., 1000m³ inner -> DMG-1150).

German Mehler PVDF

3,200–9,000 N/5cm tensile strength; CH4 permeability ≤150 ml/(m²·d·bar).

Complete Standard Package

Includes stabilizing blower, DN150 liquid safety seal, ultrasonic level & anchor plates.

Standard Models, Dimensions & Technical Specifications

Standard Model Nomenclature DMG-[Outer Volume] ([Inner Effective Biogas Volume m³]) — e.g., DMG-540(500), DMG-1150(1000), DMG-1580(1500), DMG-2100(1900), DMG-2720(2500), DMG-3460(3000), DMG-5770(5000), DMG-7080(6000)
Recommended Storage Time 1.0 Hour minimum | 2.0 Hours or more recommended per local engineering regulations
Operating Pressure Range 10 mbar to 50 mbar (Model specific: e.g., DMG-1150 operates at max 22 mbar)
Membrane Material Brand German Mehler Heytex / Chuckage Biogas-Grade Polyester + Double-Sided PVDF
Structural Wind & Snow Load Wind speed up to 110 km/h (Typhoon Grade) | Snow load ≥ 50 kg/m²
Standard Included Accessories Outer/Inner/Bottom membranes, 1x stabilizing air blower, DN150 SS304 safety water seal, 2 pairs DN150 center flanges, ultrasonic level transmitter, 45°C temp sensor, pressure gauge, SS304 anchor bolts & plates
Optional Upgrades Standby blower (1 duty + 1 standby), Ex-proof VFD constant-pressure PLC cabinet, LEL gas leak detector, electric heat tracing & auto water-refill for safety seal

Technology & Lifecycle ROI Comparison Matrix

Technology / Series Capacity / Range Performance / Lifespan OPEX / Engineering Feature Key Application Advantage
EnvironTec DMG Double Membrane20 – 20,000 m³15 – 20 Years (PVDF)Zero rail greasing or anti-rust painting3–5 Days Bolted Installation on Flat Slab
Wet Spiral Steel Gas Holder500 – 10,000 m³8 – 10 Years (H2S Corrosion)High (Annual painting + winter water heating)3–6 Months Heavy Field Welding
Low-Grade PVC Gas Balloon20 – 500 m³2 – 3 Years (UV Cracking)Cannot regulate pressure; high leak riskUnprotected against wind/rain

Engineering & Sizing FAQ

Q: Why is a 1,000 m³ effective biogas storage requirement matched with Model DMG-1150?

In double membrane gas holder engineering, the outer air-pressurized membrane hemisphere must be slightly larger than the inner biogas membrane to accommodate the bottom anchor ring angle and air buffer space. Model DMG-1150 provides an exact 1,000 m³ inner biogas storage capacity within a 1,150 m³ outer dome (Φ13.75m diameter × 10.31m height, 18 anchor plates, 22 mbar max pressure).

Q: What civil foundation information does EnvironTec provide during preliminary sizing?

For every DMG model, our engineering team immediately provides the exact outer ring diameter (m), dome height (m), number of foundation anchor plates (14 to 33 plates), operating pressure (mbar), and dynamic wind/anchor load calculations for your civil engineers.

📐 ENVIRONTEC 2026 STANDARD SELECTION & DIMENSION ENGINE

Online Biogas Equipment Sizing & Preliminary Dimension Selector

Quick Demo Presets:
Steps up to standard flange tier
Baseline: 2,500 ppm
Determines polishing stage
2h recommended per regulation
Standard Tier: 650 m³/h · Flange: DN150 PN10
① BIOGAS FLARE (3 TIERS) DN150 PN10
FAII-650 / FAIII-650 / FAIV-650
Optional: VK slam-shut valve, Temp sensor, CH4/O2 analyzer
② DOUBLE MEMBRANE GAS HOLDER Max 22 mbar
DMG-1150 (1000m³)
Includes blower, DN150 safety seal, ultrasonic level & anchor plates
③ BIOLOGICAL SCRUBBER (BDS) Packing: 60 m³
BDS-60 / BDS-65
PP-H spiral tower, G+F pH/ORP, heat exchanger & Siemens PLC
④ BIOGAS CHILLER & BOOSTER SKID Cooling: 23.2 kW
GC-650 / SKID-650
Dew point +4~15°C; Ex d IIB T4 explosion-proof standard
⑤ FILTER (GF) & POLISHING (DT/ACF) SS304 / 316L
GF-650 + DTII-500 / ACF
ACF removes Siloxanes & polishes H2S < 1–5 ppm for CHP/RNG
⑥ OFFICIAL QUOTATION & GA DRAWING Pre-Filled Inquiry
✉️ Email Pre-Filled Sizing Schedule (info@zcic.com.cn)
📚 ENGINEERING WHITEPAPERS & VERIFIED CASE STUDIES (LIVING KNOWLEDGE HUB)

Authoritative Sizing Guides, Fortune 500 HAZOP Cases & IoT Diagnostic Reports

📊 Jump to 18-Tier Standard Model Matrix →
📘 ENTRY 1 · ENGINEERING SIZING GUIDE 2026-11-04

500 m³/h Biogas Plant Complete Sizing Guide: BDS Biological Scrubber, DMG Gas Holder and Flare Configuration

Step-by-step engineering calculation for a 500 m³/h biogas project across 1,250 ppm, 2,500 ppm, and 5,000 ppm H2S scenarios—comparing FAII-650, FAIII-650, FAIV-650 flares, DMG-1150 (1000m³) gas holder, and BDS-30 / BDS-60 / BDS-125 scrubbers.

Read Full Whitepaper & Specs →
📗 ENTRY 2 · SOUTHEAST ASIA FLAGSHIP CASE 2026-11-04

Belt and Road Southeast Asia Benchmark: Kuala Lumpur Pantai 2 and Bunus WWTP Biogas Holders

How EnvironTec Asia Pte. Ltd. delivered tropical-grade DMG2500 Double Membrane Gas Holders and biogas conditioning systems for Malaysia's largest underground and regional sewage treatment plants.

Read Full Whitepaper & Specs →
📙 ENTRY 3 · FORTUNE 500 INDUSTRIAL CASE 2026-11-04

Fortune 500 Industrial Biogas Benchmark: Cargill and DSM High-Standard HAZOP Desulfurization and Storage

Meeting Fortune 500 EHS and HAZOP standards in high-sulfate food, starch, and pharmaceutical wastewater anaerobic digestion with EnvironTec BDS scrubbers, DMG holders, and SKID chillers.

Read Full Whitepaper & Specs →
📕 ENTRY 4 · E-CARE™ AI TELEMETRY REPORT 2026-11-04

Based on 5,740 IoT Telemetry Points: How to Intercept Biological Scrubber Thermal Tower Death and 90.6% Oxygen Waste

Real diagnostic case study from a 10,600 Nm³/d MSW biogas plant showing how E-Care™ Smart IoT detected 66.5% thermal stress (>38°C), 90.6% oxygen overdose, and calibrated 17.8 L/d (3.6 cm/d) NPKR dosing.

Read Full Whitepaper & Specs →
🌴 ENTRY 5 · SOUTHEAST ASIA POME SOLUTION 2026-11-04

Palm Oil Mill Effluent (POME) Biogas Desulfurization and Flaring in Malaysia and Indonesia: Sizing Guide

Tailored for Indonesian and Malaysian palm oil mills treating high-temperature POME lagoon biogas without chemical NaOH imports—cutting OPEX by 75% while generating renewable CHP power and CDM carbon credits.

Read Full Whitepaper & Specs →
🔥 ENTRY 6 · LANDFILL GAS & CHP POLISHING 2026-11-04

Landfill Gas (LFG) Engineering Guide: FAIV 90mbar Booster Enclosed Flares and ACF Siloxane Removal Filters

Solving negative-pressure landfill gas extraction and CHP cylinder silica fouling using EnvironTec FAIV VFD-boosted enclosed flares (90 mbar) and GC+ACF deep dehydration and siloxane adsorption trains.

Read Full Whitepaper & Specs →
🛡️ ENTRY 7 · STRUCTURAL & SAFETY ENGINEERING 2026-11-04

Engineering Double Membrane Gas Holders (DMG) for 110 km/h Coastal Typhoons and 50 kg/m² Snow Loads

Detailed structural mechanics of Austrian ENTEC (1992) 3/4-sphere gas holders across 20 standard models, explaining hoop stress scaling (50 mbar down to 10 mbar) and triple overpressure protection.

Read Full Whitepaper & Specs →
🇸🇬 ENTRY 8 · SINGAPORE LOCAL BENCHMARK 2026-11-04

Singapore Biopharmaceutical Park Wastewater Biogas Project: BDS-45 Biological Scrubber and FAIII Enclosed Flare

Executed directly under Singapore's strict NEA environmental and workplace safety codes for a premier CDMO pharmaceutical facility, showcasing compact footprint and zero-odor execution.

Read Full Whitepaper & Specs →